Title: Comparative evaluation of two commercial PET scanners, ECAT EXACT HR+ and Biograph 2, using GATE
Authors: Καρακατσάνης, Νικόλας
Σακελλιός, Ν.
Τσαντίλας, Ν.
Δικαίος, Νικόλαος
Τσούμπας, Χαράλαμπος
Contributors: Λουντός, Γεώργιος
Λουίτζη, Κ.
Βαλαής, Ιωάννης Γ.
Νικολόπουλος, Δημήτριος Σ.
Μαλαμίτση, Τζούλια
Κανδαράκης, Ιωάννης Σ.
Νικήτα, Κωνσταντίνα Σ.
Lazaro, D.
Schmidtlein, C.R.
Item type: Journal article
Keywords: Validation;Monte Carlo simulations;Επικύρωση;Προσομοιώσεις Μόντε Κάρλο
Subjects: Medicine
Physics
Ιατρική
Φυσική
Issue Date: 22-Jan-2015
2006
Date of availability: 22-Jan-2015
Publisher: Elsevier Science Ltd
Abstract: Geant4 application for tomographic emission (GATE) is a generic Monte Carlo simulation platform based on a general-purpose code GEANT4 and designed to simulate positron emission tomography (PET) and single photon emission tomography systems. Monte Carlo simulations are used in nuclear medicine to model imaging systems and develop and assess tomographic reconstruction algorithms and correction methods for improved image quantification. The purpose of this study is to validate two GATE models of the commercial available PET scanner HR+ and the PET/CT Biograph 2. The geometry of the system components has been described in GATE, including detector ring, crystal blocks, PMTs etc. The energy and spatial resolution of the scanners as given by the manufacturers have been taken into account. The GATE simulated results are compared directly to experimental data obtained using a number of NEMA NU-2-2001 performance protocols, including spatial resolution, sensitivity and scatter fraction. All the respective phantoms are precisely modeled. Furthermore, an approximate dead-time model both at the level of single and coincidence events was developed so that the simulated count rate curve can satisfactorily match the experimental count rate performance curve for each scanner In addition a software tool was developed to build the sinograms from the simulated data and import them into the software for tomographic image reconstruction where the reconstruction algorithm of FBP3DRP was applied. An agreement of less than 0.8 mm was obtained between the spatial resolution of the simulated system and the experimental results. Also the simulated scatter fraction for the NEMA NU 2-2001 scatter phantom matched the experimental results to within 3% of measured values. Finally the ratio of the simulated sensitivities with sources radially offset 0 and 10 cm from the central axis of each of the two scanners reaches an agreement of less than 1% between the simulated and experimental values. This simulation code will be used in a second phase in order to study scatter phenomena and motion artifacts. The simulation results will be used to optimize image reconstruction algorithms, with emphasis on dynamic PET studies.
Description: Proceedings of the 3rd International Conference on Imaging Technologies in Biomedical Sciences -Innovation in Nuclear and Radiological Imaging: from Basic Research to Clinical Application
Language: English
Citation: Karakatsanis, N., Sakellios, N., Tsantilas, N., Dikaios, N., Tsoumpas, C., et al. (December 2006). Comparative evaluation of two commercial PET scanners, ECAT EXACT HR+ and Biograph 2, using GATE. Nuclear Instruments and Methods in Physics Research A. 569(2). pp. 368–372. Elsevier Science Ltd. Available from: http://www.sciencedirect.com [Accessed 22/09/2006]
Journal: Nuclear Instruments and Methods in Physics Research A
Type of Journal: With a review process (peer review)
Access scheme: Publicly accessible
License: Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες
URI: http://hdl.handle.net/11400/4531
Appears in Collections:Δημοσιεύσεις

Files in This Item:
File Description SizeFormat 
A comparative evaluation of two commercial.pdf319.64 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons