Please use this identifier to cite or link to this item: http://hdl.handle.net/11400/5581
Title: Scintillation screen preparation for use in digital medical systems
Authors: Βαλαής, Ιωάννης Γ.
Μιχαήλ, Χρήστος Μ.
Σεφέρης, Ιωάννης Ε.
Φούντος, Γεώργιος Π.
Καλύβας, Νεκτάριος Ι.
Contributors: Κανδαράκης, Ιωάννης Σ.
Παναγιωτάκης, Γεώργιος Σ.
Item type: Conference publication
Keywords: Powder Phosphors;Nuclear medicine;Σκόνη φωσφορικού οξέως;Πυρηνική ιατρική;Scintillation Screens;Οθόνες σπινθηρισμού;Digital Medical Imaging;Ψηφιακή Ιατρική Απεικόνιση
Subjects: Medicine
Medical physics
Ιατρική
Ιατρική φυσική
Issue Date: 3-Feb-2015
2012
Date of availability: 3-Feb-2015
Publisher: Νερατζής, Ηλίας
Σιανούδης, Ιωάννης
Βαλαής, Ιωάννης Γ.
Φούντος, Γεώργιος Π.
Abstract: Radiation detectors, employed in X-ray medical imaging, consist of a scintillating (fluorescent) screen emitting visible light coupled to optical sensors. Screens are fabricated by specially developed scintillators (phosphors). Up to now scintillation screens were prepared by sedimentation on fused silica substrate (spectrosil B) in a form of transparent disk 30mm in diameter and 3mm in thickness. A new sedimentation method is proposed by deposition of scintillation powders on rectangular Borosilicate glass substrate 22x22 mm2 with thicknesses of 0.13-0.17 mm (Waldemar Knittel-GmbH). The optical properties of the substrate were examined in terms of light absorption and transmission in the range between 200-800nm (visible range) and found adequate for use with the common scintillation powders (transmissivity 95%). New screens of various coating thicknesses were examined under medical X-ray irradiation, placed in direct contact with a CMOS (RadEye) optical detector. X-ray images of a test object demonstrate the fine quality and spatial resolution of the above screens. Due to the rectangular shape of the substrate images taken from the prepared screens are indicative for their potential use in the X-ray digital medical systems.
Description: Special issue: Workshop on Bio-Medical Instrumentation and related Engineering And Physical Sciences, Technological Educational Institute of Athens, 6 July 2012
Language: English
Citation: Valais, I.G., Michail, C.M., Seferis, I.E., Fountos, G.P., Kalyvas, N.I., et al. (2012). Scintillation screen preparation for use in digital medical systems. "e-Journal of Science & Technology". [Online] 7(3): 1-5. Available from: http://e-jst.teiath.gr/
Journal: e-Περιοδικό Επιστήμης & Τεχνολογίας
e-Journal of Science & Technology
Type of Journal: With a review process (peer review)
Access scheme: Publicly accessible
License: Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες
URI: http://hdl.handle.net/11400/5581
Appears in Collections:Τόμος 07, τεύχος 3 (2012)

Files in This Item:
File Description SizeFormat 
Valais e-jst.pdf351.03 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons