Please use this identifier to cite or link to this item: http://hdl.handle.net/11400/5596
Title: Modified polyenergetic X-ray spectra for dual energy method
Authors: Κούκου, Βάϊα Ν.
Μαρτίνη, Νίκη Δ.
Σωτηροπούλου, Παναγιώτα Ι.
Φούντος, Γεώργιος Π.
Μιχαήλ, Χρήστος Μ.
Contributors: Βαλαής, Ιωάννης Γ.
Κανδαράκης, Ιωάννης Σ.
Νικηφορίδης, Γεώργιος Χ.
Item type: Conference publication
Keywords: Nuclear medicine;Mammography;Πυρηνική ιατρική;Μαστογραφία;K-edge techniques;Τεχνικές αιχμής Κ;Dual energy x-ray;Ακτίνες Χ διπλής ενέργειας;X-ray simulations;Προσομοιώσεις ακτίνων Χ;Bone densitometry;Οστική πυκνότητα
Subjects: Medicine
Medical physics
Ιατρική
Ιατρική φυσική
Issue Date: 3-Feb-2015
2012
Date of availability: 3-Feb-2015
Publisher: Νερατζής, Ηλίας
Σιανούδης, Ιωάννης
Βαλαής, Ιωάννης Γ.
Φούντος, Γεώργιος Π.
Abstract: The aim of the present study was the optimization of polyenergetic x-ray spectra for Dual energy imaging. The latter was accomplished by using various combinations of filter thicknesses and kVp. X-ray spectra were optimized by using double track x-ray tubes equipped with Molybdenum (Mo) and Rhodium (Rh), Mo and Tungsten (W), Rh and W, and a W or Rh anode combined with various Kedge filters and combinations. Filtering of energy spectra was implemented by determining the optimum combination and thicknesses of the lanthanides filters. The filtered spectra were normalized at standard exposure conditions. Best performance characteristics were obtained from the combination of Rh anode spectrum at 25kVp filtered with 100 μm Rh for low energy, and W anode spectrum at 50Vp filtered with 400 μm Ce for mammography, with mean energy values 19.57 and 30.10KeV respectively. For bone densitometry, best results were obtained from a W anode filtered spectrum at 110KVp with 900 μm Ce and mean energy values 37.78 and 85.56KeV for low and high energy respectively.
Description: Special issue: Workshop on Bio-Medical Instrumentation and related Engineering And Physical Sciences, Technological Educational Institute of Athens, 6 July 2012
Language: English
Citation: Koukou, V.N., Martini, N.D., Sotiropoulou, P.I., Fountos, G.P., Michail, C.M., et al. (2012). Modified polyenergetic X-ray spectra for dual energy method. "e-Journal of Science & Technology". [Online] 7(3): 79-85. Available from: http://e-jst.teiath.gr/
Journal: e-Περιοδικό Επιστήμης & Τεχνολογίας
e-Journal of Science & Technology
Type of Journal: With a review process (peer review)
Access scheme: Publicly accessible
License: Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες
URI: http://hdl.handle.net/11400/5596
Appears in Collections:Τόμος 07, τεύχος 3 (2012)

Files in This Item:
File Description SizeFormat 
Foundos-Sotirop e-jst.pdf651.61 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons