Title: Wall heat loss from intermittently conditioned spaces
Alternative title / Subtitle: the dynamic influence of structural and operational parameters
Authors: Τσιλιγγίρης, Παναγιώτης Θ.
Item type: Journal article
Keywords: Transient wall performance;Intermittent heating load;Heat capacity distribution;Wall thermal time constant;Building heat transfer;Παροδική απόδοση τοίχο;Διαλείπον φορτίο θέρμανσης;Κατανομή θερμικής ικανότητας;Κτίριο μετάδοσης θερμότητας
Subjects: Technology
Engineering
Τεχνολογία
Μηχανική
Issue Date: 4-May-2015
Aug-2006
Date of availability: 4-May-2015
Publisher: Elsevier
Abstract: The intermittent daily operation of the HVAC equipment is currently a method usually adopted for reasons of proper building energy management in geographical regions with temperate climatic conditions. Under these conditions, the influence of the building envelope and the specific operational schedule of the mechanical equipment under the effect of time-varying ambient temperature and incident solar radiation is responsible for the development of complex transient heat transfer phenomena, which leads to continuous heat exchange with the environment. The heat exchange through the building envelope, which determines its energy efficiency, is strongly influenced by several parameters along with the thermal characteristics of the building elements like the wall thermal resistance and heat capacity as well as the thermal time constant and operational conditions of mechanical equipment. In the present investigation, an analysis is developed for the evaluation of the daily quasi steady-state energy losses from composite walls under the effect of time-varying meteorological driving forces, when heating at the room side is intermittent. The effect of various significant design and system operational parameters like wall heat capacity, thermal time constant and the insulation layer configuration, daily heating cycle duration and phase, as well as room heat capacity and net heating power input are investigated on the quasi steady-state energy loss and daily room temperature swing under typical winter conditions.
Language: English
Citation: TSILINGIRIS, P.T. (2006). Wall heat loss from intermittently conditioned spaces: the dynamic influence of structural and operational parameters. Energy and Buildings. [Online] 38 (8). p.1022–1031. Available from: http://www.sciencedirect.com/[Accessed 03/02/2006]
Journal: Energy and Buildings
Type of Journal: With a review process (peer review)
Access scheme: Publicly accessible
License: Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες
URI: http://hdl.handle.net/11400/9630
Appears in Collections:Δημοσιεύσεις

Files in This Item:
File Description SizeFormat 
1-s2.0-S0378778805002355-main.pdf325.33 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons